ASCO SERIES 185 RESIDENTIAL TRANSFER SWITCH

ASCO SERIES 300G INDUSTRIAL TRANSFER SWITCH

ASCO SERIES 300 INDUSTRIAL TRANSFER SWITCH

MANUAL TRANSFER SWITCHES

 

SERVICE ENTRANCE RATED AUTOMATIC TRANSFER SWITCHES

 

THE ASCO SERVICE ENTRANCE RATED AUTOMATIC TRANSFER SWITCHES, COMBINE A SERVICE ENTRANCE DISCONNECT, AND A AUTOMATIC TRANSFER SWITCH INTO A EASY TO INSTALL SPACE SAVING PACKAGE.

THEY ARE AVAILABLE IN THE SERIES 185 FOR HOME AND SMALL BUSINESS USE,
 AND THE SERIES 300 FOR INDUSTRIAL AND COMMERCIAL APPLICATIONS

 

QUESTIONS or want to place a PHONE ORDER

Please call us toll free at (866)321-6855 or e-mail us at
sales@biglakesupply.com

(we're open from 9-5 central time Monday through Friday)

 

 

 

 

SERIES 185  SERVICE ENTRANCE RATED AUTOMATIC GENERATOR TRANSFER SWITCH

The series 185 Service Entrance Rated Automatic transfer switch has all of the features and functionality of the standard series 185, with the addition of a utility side circuit breaker.

The ASCO series 185 Service Entrance Rated Automatic Transfer Switch is fully rated and UL listed for use as "service entrance" equipment.

24 HOUR PROTECTION AGAINST POWER FAILURES

Residential power outages can jeopardize homeowner personal safety and comfort, and also cause millions of dollars in damages to small businesses each year.

Computers, communications, air conditioning, security systems, refrigerators and freezers, hot water heaters and sump pumps all depend on electrical power to operate.

A generator is one piece of the solution. An ASCO Series 185 Power Transfer Switch is the other, the vital link that makes continuous power hassle free.

ASCO Series 185 Power Transfer Switches provide all  the intelligence your generator needs to make sure the power stays on when utility power fails. Sensing the loss of utility power and signaling the generator to start and restore power to your home or business even if no one is home. When utility power has been restored, the Series 185 Power Transfer Switch automatically transfers your vital loads back to the utility and shuts the generator down.

Working hand in hand with virtually every brand of generator, ASCO Series 185 Power Transfer Switches provide around-the-clock protection from a power failure, taking action only when required.

ASCO Series 185 Power Transfer Switches are suitable for operation with portable or permanently mounted standby generators supporting loads up to 200 Amperes.

 

 

 

FEATURES AND SPECIFICATIONS

  • User-friendly control interface with easy to understand symbols and visual indicators to inform operator of transfer switch and power source status

  • Listed to UL 1008 for optional standby systems, handling total system load including motors and all other electrical loads

  • cUL Listed for Canadian installations

  • Meets Article 702, NFPA-70 National Electric Code (NEC) requirements

  • Nominal service voltage 240V 50/60Hz, single phase, 3 wire AC systems

  • True double-throw contacts with inherent mechanical interlocking to prevent connection of generator and utility sources

  • Terminals for convenient connection of neutral and ground conductors

  • Textured RAL 7035 light beige color aesthetically suitable for residential applications

  • Available in NEMA Type 1 Indoor (steel) and Type 3R Outdoor (aluminum) enclosures, with hinged door designs

  • NEMA 1 size is 36.4"H x 16.3"W x 6.1"D

  • NEMA 3R size is 37.4"h x 16.3"w x 8.1"D

  • Adjustable 1 or 3 second time delay for overriding momentary utility source disruptions

  • 10 second time delay before load transfer to emergency source, to allow generator warm-up and stabilization

  • Adjustable 0 or 4 second time delay while on standby source to ignore momentary generator voltage dips

  • 15 minute time delay before load retransfer back to utility source, to ensure stability of utility power

  • Adjustable 2 or 5 minute unloaded running time delay allows generator to cool down prior to shutdown

  • Weekly generator exerciser with or with out load transfer.

  • 50 or 60 hertz operation

  • Listed to UL 891 Standard for Switchboards, and meets all NEC requirements for service entrance equipment.

  • Circuit Breaker disconnect on the normal source for isolation of transfer switch and  other electrical equipment.

  • Meets National Electrical Code (NEC) and National Fire Protection Association (NFPA) requirements.

 

 

 

Push Buttons
On the front control display are three push buttons that control the operation of the generator and the ATS.

Transfer Test:
Use this button to test the system. This operation starts the generator and transfers the load.

Bypass Time Delay:
Use this button to cancel the active time delay or exercise period (stops the generator after cooldown).

Set Engine Exerciser:
Use this button to set the automatic generator exerciser

 

Indicator Lights
On the front control display are five lights that indicate the status of the sources and the ATS.

Utility Acceptable:
This light indicates that the utility voltage is acceptable for connection to the load

Load on Utility, Load on Generator:
These two lights indicate which source (utility or generator) is connected to the load

Generator Acceptable:
This light indicates that the generator voltage is acceptable for connection to the load

Automatic Generator Exerciser:
When the utility is acceptable and the load is on the utility, this light flashes the number of days until the next exercise period. When it is off, no exerciser period is set. The light is also off when the generator is running

 

 

SERIES 185 AUTOMATIC GENERATOR TRANSFER SWITCH MANUALS

Owners manual (1.1mb) Brochure (1.5mb)
Cut Sheet (158 kb) SE RATED NEMA 1 construction drawing (120 kb)
SE RATED NEMA 3R construction drawing (132 kb)  

 

WE CAN SHIP YOUR GENERATOR TRANSFER SWITCH TODAY

AND UPS GROUND SHIPPING IS FREE, THAT'S RIGHT...FREE SHIPPING

(Within the continental United States. Our UPS cutoff is at 09:00 AM PST, M-F. If we get your order before the cutoff time we can generally get it shipped the same day, otherwise we'll ship it the next business day)

NEED YOUR TRANSFER SWITCH TOMORROW?

We can ship any transfer switch via overnight or 2 day air service anywhere in the world. Please call for a freight quote for this service.

 

Official PayPal Seal

 

ASCO SERIES 185 SERVICE ENTRANCE RATED AUTOMATIC TRANSFER SWITCH PRICES

We currently stock the 200 amp NEMA 3R version of this switch due to it's high popularity; and can ship it right away.
The other versions of this switch are built to order, and have a factory lead time of 3 to 5 weeks so please plan accordingly.

ASCO SERIES 185 SE RATED ATS, 200 AMP, 2 POLE, 120/240 VOLT, NEMA 1 ENCLOSURE, P/N 1AUSA2200F4C $1515..00 *** LIMITED SUPPLY, 3 TO 5 WEEK LEAD TIME ***
ASCO SERIES 185 SE RATED ATS, 200 AMP, 2 POLE, 120/240 VOLT, NEMA 3R ENCLOSURE, P/N 1AUSA2200F4M $1664.00 *** IN STOCK AND READY TO SHIP ***

ASCO SERIES 185 AUTOMATIC TRANSFER SWITCH ACCESSORIES
(ACCESSORY PRICES ARE BASED ON THE PURCHASE OF A SERIES 185 ATS AT THE SAME TIME, PLEASE CONTACT US FOR ALA CART PRICING)

ASCO STRIP HEATER FOR NEMA 3R TRANSFER SWITCHES P/N K732212 (RECOMMENDED FOR TEMPERATURES BELOW FREEZING) $145.00
 

 

The ASCO SERIES 300 Service Entrance Rated Automatic Transfer Switch combines automatic power switching with a utility circuit breaker as a disconnect device. The power transfer switch meets all National Electrical Code requirements for installation as service entrance equipment.

The ASCO 300SE Service Entrance Automatic Transfer Switch uses the same reliable transfer switching mechanism, and controller as the series 300 product platform, and also includes a utility circuit breaker as a disconnect device.

GENERATOR TRANSFER SWITCH CONTROL PANEL

SERVICE ENTRANCE DISCONNECT

 

STANDARD FEATURES

  • Suitable for use as service entrance equipment.

  • The ASCO Series 300SE is listed to UL 891 standard for Dead-Front Switchboards, and meets all NEC requirements for service entrance equipment.

  • Automatic Transfer Switch is listed to UL 1008 for total system loads.

  • Sizes available from 150 through 3000 amps.

  • Available to 600 VAC, 50 or 60Hz, single or three phase.

  • Circuit Breaker disconnect on the normal for isolation of transfer switch and other electrical equipment.

  • Disconnect link on Neutral and Ground.

  • Silver plated copper ground and neutral bus.

  • Solderless screw type terminals for External Power Connections.

  • Ground fault trip protection provided on sizes of 1000 amperes and above.

  • UL approved Type 1 enclosure.

  • Available with solid or switched neutral.

  • Motor load transfer controls (inphase monitor) to keep motors operating during transfer.

  • Pre-transfer & post-transfer load disconnect contacts for signaling motor starters, elevators, VFDs and other selected loads.

  • Standard Engine Exerciser for weekly automatic testing of engine generator set with or without load.

  • Selectable control switches for voltage, frequency, time delay settings & additional control features.

  • Switch position lights, source availability lights, test switch and time delay bypass switch.

TIME DELAYS

  • Adjustable time delay to over ride momentary normal source outages to delay all transfer switch and engine-starting signals.

  • Transfer to emergency time delay. Adjustable from 0 to 5 minutes for controlled timing of load transfer to emergency.

  • Retransfer to normal time delay. Adjustable to 30 minutes.

  • Five-minute unloaded running time delay for emergency engine generator cool down.

  • Four-second time delay to override momentary to ignore momentary voltage and frequency transients during initial genset loading.

VOLTAGE & FREQUENCY SENSING

  • Adjustable three-phase, close differential voltage sensing on normal source.

  • Normal source pickup voltage is adjustable to 95% of nominal; drop-out is adjustable from 70 to 90% of nominal.

  • Frequency sensing on emergency source. Pickup at 95% and dropout at 85% of nominal.

STANDARD CONTROL CONTACTS

  • Switch position indicating contacts (rated 10 amps 250VAC, 32VDC). (1) for Normal position, (1) for Emergency position.

  • Gold plated engine start contacts (rated 5 amps 28VDC or 120VAC).

REMOTE CONTROL FEATURES

  • Remote test switch.

  • Remote contact for test or for peak shaving applications. Circuit will be automatically bypassed if emergency source fails.

  • Inhibit transfer to emergency.

  • Remote time delay bypass switch.

 

 

SERIES 300  AUTOMATIC TRANSFER SWITCH DOCUMENTS(

MOST OF THESE DOCUMENTS, DO NOT INCLUDE THE SERVICE ENTRANCE DISCONNECT IN THEM. ASCO USES THE SAME MANUALS FOR THE STANDARD AND THE SERVICE ENTRANCE RATED SERIES 300 ATS.)

Operators manual, 30-225 amp (456kb)

Brochure (2.1mb) Suggested bid specifications (63kb)

Operators manual, 260-400 amp (1.1mb)

Deluxe engine exerciser manual (145kb) Warranty (94kb)
Operators manual,600-1200  amp (515kb) Dimensional data Cut Sheet

 

WE HAVE A LIMITED STOCK ON HAND OF ASCO SERIES 300
SERVICE ENTRANCE RATED AUTOMATIC TRANSFER SWITCHES.

PLEASE CALL US FOR OUR CURRENT INVENTORY, AND LEAD TIMES FOR UNITS THAT ARE OUT OF STOCK.

 

ASCO SERIES 300 SE PRICES

200 AMP 2 POLE, 120,240 VOLT, NEMA 1 ENCLOSURE $3539.00
200 AMP 2 POLE, 120,240 VOLT, NEMA 3R ENCLOSURE $3938.00
400 AMP 2 POLE, 120,240 VOLT, NEMA 1 ENCLOSURE $4827.00
400 AMP 2 POLE, 120,240 VOLT, NEMA 3R ENCLOSURE $5395.00
400 AMP 3 POLE, ANY VOLTAGE, NEMA 1 ENCLOSURE $5258.00
400 AMP 3 POLE, ANY VOLTAGE, NEMA 3R ENCLOSURE $5841.00

 

DON'T SEE THE AUTOMATIC TRANSFER SWITCH YOU'RE LOOKING FOR?

Call us toll free at (866)321-6855

or E-mail us at sales@biglakesupply.com

We can supply you with any ASCO series 185 or 300 Automatic Transfer Switch, at the lowest prices in the country.

 

Copyright 1999-2014 TransferSwitch4Less.com - Automatic Transfer Switch - ASCO Transfer Switch.